Test |
Commonly followed standards |
Capabilities |
---|---|---|
Radiated Emission |
CISPR / FCC & Similar |
Upto 10m inside Shielded Anechoic Chamber(SAC) 30 MHz- 6 GHz |
Conducted Emission |
CISPR / FCC & Similar |
9 kHz -30 MHz Power Line/Signal Line/Telecom Port LISN/AMN, Current Clamp & Voltage Probe |
Radiated RF Power Disturbance |
CISPR 14 & Similar |
30 MHz - 300 MHz Power Line using Absorbing Clamp |
Harmonic Current Emission |
IEC 61000-3-2 & Similar |
Up to 40th harmonics (Odd & Even) 230 VAC / 16 A single phase |
Flicker Emission |
IEC 61000-3-3 & Similar |
Pst (10 minutes), Plt (1 hour) 230 VAC / 16 A single phase |
Electro Static Discharge |
IEC 61000-4-2 & Similar |
Upto ±30 kV Air / Contact /In-Direct Discharge Networks: 150pf/330 ohm (Refer automotive section for other networks) |
Radiated Susceptibility |
IEC 61000-4-3 & Similar |
80 MHz - 6 GHz upto 30 V/m |
Electrical Fast Transient |
IEC 61000-4-4 & Similar |
Burst frequency 5 kHz & 100 kHz Upto ±4 kV |
High Energy Surge |
IEC 61000-4-5 & Similar |
Upto ±6 kV |
Telecom Surge |
IEC 61000-4-5 & Similar |
Upto ±6 kV |
Conducted RF Immunity |
IEC61000-4-6 & Similar |
upto 30 Vrms 150 kHz - 230 MHz |
Power Frequency Magnetic Field Immunity |
IEC 61000-4-8 & Similar |
upto 1000 A/m |
Pulse Magnetic Field Immunity |
IEC 61000-4-9 & Similar |
Up to 1000 A/m |
Damped Oscillatorry Magnetic Field Immunity |
IEC 61000-4-10 & Similar |
220 A/m for 100 kHz 110 A/m for 1 MHz |
Voltage Dips, Short Interruptions and Voltage Variations Immunity Test |
IEC 61000-4-11 & Similar |
Voltage Dips :0%-0.5 &1 cycle, 40%-10/12 cycle, 70%-25/30 cycle, 80%-250/300 cycles. Short interruptions:0%-250/300 cycles. Voltage variation: 70%-25/30 cycles |
Ring Wave Immunity |
IEC 61000-4-12 & Similar |
100kHz Up to ±6 kV |
Harmonics and Interharmonics ImmunityRecently upgraded |
IEC 61000-4-13 & Similar |
|
Voltage Fluctuation Immunity ImmunityRecently upgraded |
IEC 61000-4-14 & Similar |
|
Ripple on DC Input Power Port ImmunityRecently upgraded |
IEC 61000-4-17 & Similar |
|
Damped Oscillatorry Immunity (Slow Damped) |
IEC 61000-4-18 & Similar |
100 KHz & 1 MHz Up to ±4.4 kV |
Variation of Power Frequency ImmunityRecently upgraded |
IEC 61000-4-28 & Similar |
|
DC Voltage Dips, Short Interruptions and Voltage variations |
IEC 61000-4-29 & Similar |
0%, 40%, 70%, 80% & 120% |
Test |
Standard (not limited to) |
Capabilities |
---|---|---|
Radiated Emission |
CISPR 25 & Similar |
150 kHz - 2.5 GHz |
Conducted Emission |
CISPR 25 & Similar |
150 kHz - 108 MHz Voltage/Current method Power line/signal line |
Conducted Transient Emission test |
ISO 7637-2 & Similar |
Slow pulse Fast pulse Power line/signal line |
Conducted transient Immunity test |
ISO 7637-2 & Similar |
Pulse 1, 2a, 2b, 3a, 3b, 4, 5a & 5b Max input 60V/32A Power line |
Conducted transient Immunity test |
ISO 7637-3 & Similar |
Pulse 3a,3b Signal line |
Radiated Susceptibility |
ISO 11452-2, AIS-004 Part3 & Similar |
80 MHz - 2 GHz 10 V/m Enclosure |
Bulk current injection |
ISO 11452-4 & Similar |
up to 200mA 1 MHz – 400 MHz Signal line |
ESD |
ISO 10605 & Similar |
Upto± 30kV Networks: 150pF/330 ohm 330pF/330 ohm 330pF/2000 ohm 150pF/2000 ohm |
Test |
Standard (not limited to) |
Capabilities |
---|---|---|
Conducted emission, CE101 |
Mil-Std-461 E/F/G |
Power leads, Current 30Hz-10kHz Single phase: 16A Three phase: 32A DC: 50A |
Conducted emission, CE102 |
Mil-Std-461 E/F/G |
Power leads, Voltage 10kHz - 10MHz Single phase: 16A Three phase: 32A DC: 50A |
Radiated emission, RE101 |
Mil-Std-461 E/F/G |
Magnetic field Enclosure 30Hz to 100kHz |
Radiated emission, RE102 |
Mil-Std-461 E/F/G |
Electric field Enclosure 10kHz to 18GHz |
Conducted susceptibility, CS101 |
Mil-Std-461 E/F/G |
Power leads 30Hz to 150kHz AC: 300V max., 20A DC: 60V max., 30A |
Conducted susceptibility, CS114 |
Mil-Std-461 E/F/G |
Bulk current injection Power leads and signal cables 10kHz to 200MHz |
Conducted susceptibility, CS115 |
Mil-Std-461 E/F/G |
Impulse transient Power leads and signal cables |
Conducted susceptibility, CS116 |
Mil-Std-461 E/F/G |
Damped sinusoidal transient Power leads and signal cables |
Conducted susceptibility, CS118 |
Mil-Std-461 G |
Personnel borne electrostatic discharge 150pF, 330ohm network Up to 30kV |
Radiated susceptibility, RS101 |
Mil-Std-461 E/F/G |
Magnetic field Enclosure 30Hz to 100kHz |
Radiated susceptibility, RS103 |
Mil-Std-461 E/F/G |
Electric field Enclosure 2MHz to 40GHz, up to 200V/m |